CCNA 200-301 v2.0 · Original practice content aligned to the official v2.0 exam topics

CCNA v2.0 Practice Questions: Network Infrastructure and Connectivity

Diagnose interface and cabling faults, troubleshoot IPv4/IPv6 addressing and DHCP, and fix wired and wireless client connectivity.

Domain 1.0 is 25% of CCNA v2.0. Topics: interface and cable faults (copper and fiber), hypervisors, VMs and containers, IPv4 and IPv6 addressing and subnetting, wireless principles, client connectivity on Windows, macOS and Linux, and DHCPv4 client, server and relay.

CCNA v2.0 starts February 3, 2027 and runs 120 minutes. The current v1.1 exam is available until February 2, 2027.

Domain sample questions with answers

Network Infrastructure and Connectivity

CCNA v2.0 sample question 1

Users complain of slow file transfers from the server on SW1 GigabitEthernet1/0/5. The server NIC is set to auto-negotiate and reports 1000 Mb/s full duplex. SW1 shows:

GigabitEthernet1/0/5 is up, line protocol is up (connected)
  Full-duplex, 1000Mb/s, media type is 10/100/1000BaseTX
     0 runts, 0 giants, 0 throttles
     4127 input errors, 4119 CRC, 8 frame, 0 overrun, 0 ignored
     0 output errors, 0 collisions, 2 interface resets

What is the most likely cause?

  1. A duplex mismatch between the port and the NIC
  2. Egress congestion that overflows the output queue
  3. A damaged cable or electrical interference on the run
  4. Jumbo frames from the NIC exceeding the port MTU
Show correct answer and explanation

Correct answer: C. A damaged cable or electrical interference on the run

C is correct because both ends agree on 1000 Mb/s full duplex and there are no collisions, so CRC errors point to signal corruption on the physical path. A would show runts or late collisions and differing duplex, but both ends report full duplex. B would raise output drops, not CRC errors on received frames. D would increment the giants counter, which is zero here.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 2

A help desk ticket says the lobby kiosk lost its network connection. On SW3, show interfaces status shows:

Port      Name               Status       Vlan       Duplex  Speed Type
Gi1/0/12  Lobby-Kiosk        err-disabled 20           auto   auto 10/100/1000BaseTX
Gi1/0/13  Lobby-Cam          connected    20         a-full  a-100 10/100/1000BaseTX

What should the engineer do to restore the kiosk port?

  1. Enter no shutdown only, since the port was disabled by an administrator
  2. Replace the patch cable because the port has lost its physical link
  3. Fix the violation, then enter shutdown and no shutdown on the port
  4. Hard-code speed and duplex to clear the failed negotiation on the port
Show correct answer and explanation

Correct answer: C. Fix the violation, then enter shutdown and no shutdown on the port

C is correct because err-disabled means a feature such as port security or BPDU guard shut the port, and it returns only after the cause is removed and the port is bounced. A describes the disabled status; an administratively shut port would show disabled, not err-disabled. B describes the notconnect status; err-disabled is a software shutdown, not a missing link. D would not help, because negotiation failures do not place a port in the err-disabled state.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 3

A user reports that the link light on their desktop NIC is off. On SW2, show interfaces status shows:

Port      Name               Status       Vlan       Duplex  Speed Type
Gi1/0/7   Desk-214           notconnect   10           auto   auto 10/100/1000BaseTX
Gi1/0/8   Desk-215           connected    10         a-full a-1000 10/100/1000BaseTX

What is the most likely explanation?

  1. The port was shut down with the shutdown command
  2. No physical link, such as an unplugged or faulty cable
  3. The port is assigned to the wrong access VLAN
  4. The port was error-disabled by a security feature
Show correct answer and explanation

Correct answer: B. No physical link, such as an unplugged or faulty cable

B is correct because notconnect means the port is enabled but detects no link partner, which matches a dark link light. A would show the status disabled rather than notconnect. C would still show connected with a link light, since VLAN membership does not affect Layer 1. D would show the status err-disabled rather than notconnect.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 4

A newly installed router uplink is not passing traffic. On R2, show interfaces GigabitEthernet0/1 begins with:

GigabitEthernet0/1 is administratively down, line protocol is down
  Hardware is ISR4331-3x1GE, address is 0050.56a1.0b01 (bia 0050.56a1.0b01)
  Internet address is 192.0.2.1/30

Which interface command will bring the interface up?

  1. duplex auto
  2. speed auto
  3. no shutdown
  4. errdisable recovery cause all
Show correct answer and explanation

Correct answer: C. no shutdown

C is correct because administratively down means the interface is disabled in the configuration, and no shutdown enables it. A changes duplex negotiation but does not enable an interface that is shut down. B changes speed negotiation but does not enable an interface that is shut down. D applies to err-disabled ports, not to an interface disabled by the shutdown command.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 5

A file server on SW4 FastEthernet0/10 is connected with a 3-meter patch cord and performs poorly. SW4 shows:

FastEthernet0/10 is up, line protocol is up (connected)
  Half-duplex, 100Mb/s, media type is 10/100BaseTX
     0 runts, 0 giants, 0 throttles
     1523 output errors, 2290 collisions, 0 interface resets
     0 babbles, 1488 late collision, 35 deferred

What do the counters most likely indicate?

  1. The patch cord exceeds the maximum copper distance
  2. A duplex mismatch with the server running full duplex
  3. A speed mismatch between the switch and the server
  4. An MTU mismatch causing oversized frames
Show correct answer and explanation

Correct answer: B. A duplex mismatch with the server running full duplex

B is correct because late collisions on a half-duplex port with a short cable are the classic sign that the far end is transmitting in full duplex. A cannot be the cause because a 3-meter cord is far below the 100-meter limit. C would keep the link down, but the port is up at 100 Mb/s. D would raise the giants counter, which is zero.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 6

A 1000BASE-LX link between two buildings has intermittent drops. The module's Rx low alarm threshold is -20.0 dBm. SW5 show interfaces transceiver shows:

Port      Temperature(Celsius)  Voltage(Volts)  Current(mA)  Optical Tx Power(dBm)  Optical Rx Power(dBm)
Gi1/0/49  31.2                  3.29            22.1         -6.1                   -24.6 --
Gi1/0/50  30.8                  3.28            21.7         -5.9                   -7.3

What is the best next step?

  1. Replace the local SFP on Gi1/0/49 because its Tx power is too low
  2. Hard-code duplex full on Gi1/0/49 to stabilize the fiber link
  3. Clean and inspect the fiber connectors and check the path for loss
  4. Install an inline attenuator on Gi1/0/49 to reduce the signal level
Show correct answer and explanation

Correct answer: C. Clean and inspect the fiber connectors and check the path for loss

C is correct because Rx power on Gi1/0/49 is flagged -- below the low alarm while the local Tx is normal, which points to loss from dirty connectors, bends or bad splices. A misreads the output, since -6.1 dBm Tx is normal and matches the healthy port. B does not address optical power, and gigabit fiber links already run full duplex. D would lower an already weak signal; attenuators fix Rx power that is too high.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 7

The storage team changed a server NIC on SW6 GigabitEthernet1/0/30 to an MTU of 9000, and the switch system MTU is 1500. SW6 now shows:

GigabitEthernet1/0/30 is up, line protocol is up (connected)
  Full-duplex, 1000Mb/s, media type is 10/100/1000BaseTX
     0 runts, 18342 giants, 0 throttles
     18342 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored

What is causing the input errors?

  1. Bit errors on the copper cable that fail the FCS check
  2. Frames larger than the switch port MTU arriving from the server
  3. Frames shorter than 64 bytes caused by collisions
  4. A receive buffer that cannot keep up with the input rate
Show correct answer and explanation

Correct answer: B. Frames larger than the switch port MTU arriving from the server

B is correct because every input error is a giant, which matches jumbo frames from the server exceeding the 1500-byte switch MTU. A would raise the CRC counter, which is zero here. C describes runts, and the runts counter is zero on this full-duplex port. D would raise the overrun or ignored counters, which are zero.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 8

Users between SW1 and SW2 report slow transfers. SW1 Fa0/24 and SW2 Fa0/24 show:

SW1 Fa0/24:
  Half-duplex, 100Mb/s
     0 runts, 0 giants
     0 input errors, 0 CRC
     2511 collisions, 1876 late collision

SW2 Fa0/24:
  Full-duplex, 100Mb/s
     1032 runts, 0 giants
     2210 input errors, 2194 CRC
     0 collisions, 0 late collision

An AI assistant says: "The CRC errors on SW2 show a faulty cable; replace the patch cord." Which assessment of the recommendation is correct?

  1. Reject it; the runts on SW2 show an MTU mismatch between the switches
  2. Reject it; late collisions on the half-duplex end show a duplex mismatch
  3. Accept it; CRC errors on any port always point to a faulty cable
  4. Accept it; the cable is too long, which causes the late collisions
Show correct answer and explanation

Correct answer: B. Reject it; late collisions on the half-duplex end show a duplex mismatch

B is correct because SW1 is half duplex with late collisions while SW2 is full duplex with runts and CRC errors, the signature of a duplex mismatch. A misreads runts, which are undersized frames, while MTU mismatches cause giants. C ignores that the full-duplex side of a duplex mismatch also logs CRC errors and runts. D cannot explain why one end is half duplex and the other full duplex.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 9

Two buildings 400 meters apart are linked over single-mode fiber with 1000BASE-ZX optics, and the link takes errors. SW7 show interfaces transceiver detail shows:

Port      Optical Receive Power(dBm)  High Alarm  High Warn  Low Warn  Low Alarm
Gi1/0/50  1.4 ++                      -3.0        -5.0       -21.0     -23.0

An AI assistant recommends installing an inline attenuator on the receive side. What should the engineer do with the recommendation?

  1. Reject it; Rx power is too low, so the fiber connectors need cleaning
  2. Accept it; the attenuator will raise Rx power back above the low alarm
  3. Reject it; 400 meters exceeds ZX reach, so the link needs LX optics
  4. Accept it; Rx power exceeds the high alarm and is saturating the receiver
Show correct answer and explanation

Correct answer: D. Accept it; Rx power exceeds the high alarm and is saturating the receiver

D is correct because the ++ flag shows +1.4 dBm above the -3.0 dBm high alarm, which a long-reach ZX optic over a short run causes and an attenuator fixes. A misreads the output, since +1.4 dBm is above every threshold rather than below the low alarm. B gets the effect backward, since an attenuator lowers received power. C reverses the problem, because ZX reaches far beyond 400 meters and the issue is too much power.

Network Infrastructure and Connectivity

CCNA v2.0 sample question 10

Servers on 1 Gb/s ports send nightly backups to a legacy appliance on SW8 GigabitEthernet1/0/24, and the backups run slowly. SW8 shows:

GigabitEthernet1/0/24 is up, line protocol is up (connected)
  Full-duplex, 100Mb/s, media type is 10/100/1000BaseTX
  Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 58233
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 output errors, 0 collisions, 0 interface resets

What is the most likely cause?

  1. An input buffer shortage on the switch when receiving frames
  2. A damaged cable that corrupts frames sent to the appliance
  3. A duplex mismatch between the switch port and the appliance
  4. Egress congestion as gigabit traffic funnels into a 100 Mb/s port
Show correct answer and explanation

Correct answer: D. Egress congestion as gigabit traffic funnels into a 100 Mb/s port

D is correct because output drops climb with zero errors or collisions, so the port is healthy and is dropping traffic it cannot send fast enough. A would show input queue drops or overruns, which are zero. B would show CRC or output errors, and both counters are zero. C would show late collisions or CRC errors, which are all zero.

Keep practicing CCNA v2.0

CCNA v2.0 quick start · CCNA v2.0 overview · CCNA v1.1 practice tests · CCNA cheat sheet

FlashGenius is an independent practice resource, not Cisco. These are original practice questions written against the official CCNA 200-301 v2.0 exam topics, not exam dumps. Your result is practice accuracy, not an official score.